Apc Rj45 Serial Cable Pinout

RJ45 serial pinout options and diagrams. This article illustrates the serial pinouts of Opengear RJ45 serial ports, past and present. Determine the serial pinout of your Opengear device. Adapters required to connect to various types of ports, by pinout.

TTP223 Touch Key Switch Module Touching Button Self-Locking No-Locking Capacitive Switches Single Channel For Arduino l8
Black CCL Anti-etching PCB Circuit Board Ink Marker Double Pen For DIY PCB Repair CCL Printed Circuit Diagram For Arduino
5x7 4x6 3x7 2x8 cm 5*7 4*6 3*7 2*8 double Side Copper prototype pcb Universal Printed Circuit Board Protoboard For Arduino Green
5x7 4x6 3x7 2x8 cm 5*7 4*6 3*7 2*8 double Side Copper prototype pcb Universal Printed Circuit Board Protoboard For Arduino Blue
1.27mm 1.27 Pin Header Single Row Male Breakaway PCB Board Connector Pinheader 1*2/4/5/6/8/10/12/15-40p 50p For Arduino
10PCS 2.54MM pitch single row female pin socket 2/3/4/5/6/7/8/9/10/11/12/13/14/40Pin PCB Connector Single Row Mother For arduino
0.96 inch oled serial blue yellow white OLED display module LCD display board GND SPI I2C for Arduino
diymore 2/3/4Pin 70cm Dupont Wire Female to Female Jumper Cables Connector for Arduino 3D Printer Reprap
diymore Potentiometer Resistance 1K 2K 5K 10K 20K 50K 100K 250K 500K 1M Ohm 3Pin Linear Taper Rotary Potentiometer for Arduino
2.54mm Single Row Male 2~40P Breakaway PCB Board Pin Header Connector Strip Pinheader 2/3/4/5/6/8/10/12/15/20/40Pin For Arduino
4pin KY-016 Three Colors 3 Color RGB LED Sensor Module for Arduino DIY Starter Kit KY016
100μH 3A Coil Wire Wrap Toroid Magnetic Inductor Monolayer Wire Wind Wound Inductance Coil for Arduino LM2596
DC 9V Battery Button Power Cable Battery Buckle Snaps Power Cable Connector DC 5.5*2.1 For Arduino Diy
1pcs 2x8cm 3x7cm 4x6cm 5x7cm 7x9cm Double Side PCB Board Gepyun Universal Printed Circuit Board For Arduino Experimental BLUE
18b20 Temperature Probe Temperature Sensor 18B20 Sensor Electronic chip DS18B20 TO-92 chips Waterproof for arduino Diy Kit
SUQ DC 9V Battery button power plug for Arduino Mega 2560 1280 UNO R3 132 9V battery buckle
1.27mm 1.27 Double Row Male 2~40P Breakaway PCB Board Pin Header Connector Strip Pinheader 2*3/4/5/6/7/8/10/12/15/20/40p 3-50P
TCRT5000 Infrared Reflective Sensor IR Photoelectric Switch Barrier Line Track Module For Arduino Diode Triode Board 3.3v
0.96 inch oled serial blue yellow white OLED display module LCD display board GND SPI I2C for Arduino
4pin KY-016 Three Colors 3 Color RGB LED Sensor Module for Arduino DIY Starter Kit KY016
DNIGEF 1 PCS 4pin KY-016 Three Colors 3 Color RGB LED Sensor Module for Arduino Diy Starter Kit KY016
TTP223 Touch Key Switch Module Touching Button Self-Locking No-Locking Capacitive Switches Single Channel For Arduino l8
2.54mm double row male 2~40p breakaway pcb board pin header connector strip pinheader 2 * 2/3/4/6/8/10/12/15/20/40p for arduino
2.54mm Double Row Male 2~40P Breakaway PCB Board Pin Header Connector Strip Pinheader 2 * 2/3/4/6/8/10/12/15/20/40P For Arduino
2.54mm Double Row Male 2~40P Breakaway PCB Board Pin Header Connector Strip Pinheader 2 * 2/3/4/6/8/10/12/15/20/40P For Arduino
1.27mm 1.27 Pin Header Single Row Male Breakaway PCB Board Connector Pinheader 1*2/4/5/6/8/10/12/15-40p 50p For Arduino Gepyun
RFID Sensor Proximity IC Key Tags Keyfobs Token NFC TAG Keychain 13.56MHz For Arduino for Access Control Attendance
0.5 inch Common Anode LED Digital Display Tube 7 Segment 1Bit Digital Tube Red for Arduino
Piezoelectric shock tap sensor Vibration switch module piezo sheet percussion for Arduino 51 UNO MEGA2560 r3 DIY Kit
ESP8266 Serial WIFI Module Adapter Plate ESP8266 White Baseboard Applies to ESP-07ESP-12EESP-12F Wireless Board for Arduino
2.54mm Single Row Male 2~40P Breakaway PCB Board Pin Header Connector Strip Pinheader 2/3/4/5/6/8/10/12/15/20/40Pin For Arduino
5x7 6x6 7x9 6x8 9x15 10x15 8x12 30x40 CM Single Side Prototype Diy Universal Printed Circuit PCB Board Protoboard For Arduino
TTP223 Touch Switch Module TTP223B 1 Channel Jog Digital Capacitive Touch Sensor for arduino DIY KIT
RFID Sensor Proximity IC Key Tags Keyfobs Token NFC TAG Keychain 13.56MHz For Arduino for Access Control Attendance
10PCS PCB Board SMD Turn To DIP Adapter Converter Plate SOP 8/16/14/20/24/28P SOT89 SOT23 SOT223 TO DIP SOP/MSOP/TSSOP
For Arduino DIY Jack 1Pcs 6F22 9V Battery Adapter Snap Connector Clip Lead Wires holder DC 5.5*2.1 jack Clip Power Cable
1/4/8/16 Channel TTP223 TTP224 TTP226 TTP229 Jog Digital Touch Button Sensor Capacitive Switch Modules Accessories for Arduino
1PCS ESP8266 serial WIFI Module Adapter Plate Applies to ESP-07, ESP-08, ESP-12 ESP-12F ESP-12E
TTP223 Touch Key Switch Module Touching Button Self-Locking No-Locking Capacitive Switches Single Channel For Arduino l8
10Pcs DIP IC Sockets Adaptor Solder Type Socket Kit 6 8 14 16 18 20 24 28 32 40Pin for arduino PCB Diy Kit
10pcs 2.54MM Pitch Single Row Female Pin Socket 2/3/4/5/6/7/8/9/10/11/12/13/14/40Pin PCB Connector Single Row Mother For Arduino
1PCS TCRT5000 Infrared Reflective Sensor IR Photoelectric Switch Barrier Line Track Module For Arduino Diode Triode Board 3.3v
10PCS PCB Board SMD Turn To DIP Adapter Converter Plate SOP 8/16/14/20/24/28P SOT89 SOT23 SOT223 TO DIP SOP/MSOP/TSSOP
Rc Mini Micro 9g 1.6KG Servo SG90 for RC 250 450 Helicopter Airplane Car Boat For Arduino DIY SG90 Bracket
TTP223 Touch Switch Module TTP223B 1 Channel Jog Digital Capacitive Touch Sensor for arduino DIY KIT
Mini/Micro USB to DIP Type A Female/ Male USB Adapter Converter for 2.54mm PCB Board DIY Power Supply For Arduino Module
10PCS 2.54MM pitch single row female pin socket 2/3/4/5/6/7/8/9/10/11/12/13/14/40Pin PCB Connector Single Row Mother For arduino
TTP223TTP223B Channel Jog Digital Touch Sensor Capacitive Touch Switch Modules Accessories TTP223 for Arduino Diy Kit
1PCS Rc Mini Micro 9g 1.6KG Servo SG90 for arduino RC 250 450 Helicopter Airplane Aeroplane Car Boat Remote Controller Motor
DC 9V Battery Button Power Cable Battery Buckle Snaps Power Cable Connector DC 5.5*2.1 For Arduino Diy GOHJMY
Brought to you by;
www.conserver.com

Zonker's APC UPS Console Clues

http://www.conserver.com/consoles/Clues/cons-apc.html
(updated:Jul 14, 2011, 09:26 am)

I've been a happy UPS user for many, many years now, both at homeand at work. I learned from the mistakes of others, and I've got acollection of UPSs protecting my home equipment, and the Console Lab.While I've worked with a few different vendors, I've got a preferencefor the units from American Power Conversion (APC), because many unitshave serial ports and they can report about the condition of the powercoming into the UPS. I find this information invaluable, but the APCserial interface is NOT directly (i.e. 'pin-for-pin') compatible withthe 'de-facto' DE-9RS-232 serial interface. This page is intended to share information Ihave found about the APC interface, and to explain how to connect thisuseful interface to your console servers. (I've also used the SNMPmodules for the SmartSlot interfaces on older Matrix series units, butthis page will not cover the use of SNMP over Ethernet conenctions.)

Table ofContents
The APC Smart serial interface
RJ-45 Console Server Cable Diagrams
Useful off-site URLs
Serial Port Settings
Author Credits

APC SmartUPS Console Signals

The signals for the APC SmartUPS series UPSs is shown at the right. You probably noticed first that there are no handshaking and flow control leads. You probably presumed that the ground and data leads were on the 'normal' pins. Surprise!

Notice the other, non-data pins again... the Low Battery and the No AC Input output signals could be used to drive an alarm system, and you could wire your own 'Big Red Switch' if you like, using the Power Off command input signal. (Or even a 'Big Green Switch', but that's outside the scope of this page.)

In short, you only need a 3-wire connection between the APC UPS console; transmit and receive data and ground only.

  • APC USB cable schematic Cable Pinout - Pinout search.Quick and easy to find any pinout diagrams and related information for various types of connectors and cables APC USB cable schematic Cable Pinout - Pinout cable and connector diagrams-usb, serial rs232,rj45 ethernet, vga, parallel, atx, dvi.
  • May 30, 2017 APC RJ12 serial cable pinout. Compatible with Rack PDU (AP78xx, AP79xx, AP86xx, AP88xx, AP89xx) and 2G Rack Automatic Transfer Switches (AP7752, AP7752, AP7730, AP7732, AP7721, AP7723). APC part # 940-0144A. This pinout is associated with 11 compatible devices or models.
  • The cable I'm using is the APC provided DB9-RJ45 that is specified to be used with the Config port (940-0214), then I have a male-male connector (I've tried both a crossover type and a straight through type), then an APC serial cable (940-0299A). I wonder if I have a problem resulting from the combination of cables and pinout changes.

APC supplies a specialserial cable with each UPS that has a serial console, because their interfacedoesn't match the de-facto standard initially used on the old IBM PC-AT. I recommend that you mark the cable, and hang onto it.

If you use either a 'straight-through', or a 'null-modem' DE-9 cable to connect an APC UPS to a 'normal' DE-9 interface, the UPS will see signals from the attached device. This is why you need a specialty cable or adapter.

In the case of the DTE cable (at right), the TD signal from the attached devices will cause the APC to shut off power to the UPS outlets immediately, and you won't be able to command it on with the front panel switches, until you disconnect the cable from the UPS or the host.

Specialty adapters for Console Servers

If you want to connect the UPS to a console server, I'dsuggest making a special adapter to connect withyour particular console server RJ-45 wiring scheme.

While you could make a specialty cable to go directly fromyour console server to the UPS, my suggestion is to make an RJ45-to-DE9adapter. While you can argue that adding an adapter to the chain willadd one more possible point of failure (for communications between the UPS and the console server), I'll counter with these points;

  • the risk is small, especially if the adapter is screwedonto the DE-9 of the UPS
  • you can use a stock CAT-3 or CAT-5 cable to conect theadapter to your console server
  • using an adapter on the UPS will allow you to connect theUPS quickly toanother device for diagnostics, if that becomes necessary. (Forexample; using an APC diagnostic or configurationtool on a laptop, forinstance, and then reconnecting to the console server for monitoring.)
APC RJ12 serial cable pinout diagram @ pinouts.ru

In the end, the decision is yours. My diagrams show anRJ45 female connection for building the adapter. You can use the samepinouts and use an RJ45 male if you are going to make a direct cable.(If you choose to make a cable, I suggest using an 8-wire cable, sothat the RJ45 male slug will hold the cable securely, and cut theunused leads at the DE-9 end of the cable.)

For a console connection (two-way data), you only need toconnect the signals shown as solidblack lines.(And 'nc' stands for 'No Connection', so no pin number is given.) Thepink dashed lines on the APC UPS output leads are only needed if youare going to try to use the flow control and handshaking inputs of theconsole server to track these signals.

Make Sure YouLABEL Your Adapter (or cable), so others will know whichRJ45 wiring scheme is in use! The Brother label maker folks has some'strong adhesive' versions of their TZ-style label tapes, and they areexcelent for this purpose.


Apc

Other sources of APC information

The Internet is a 'fluid' place, and I don't knnow how longeach of the URLs below will last. I've included summary information foreach link, so you can try to search for the pages if the link(s) seembroken.

There is an application, for use with Linux OS machines,called apcupsd,and the project had pointers to some useful How-To pages which have evolved into a good on-line manual, includingpointers to cabling information, and a useful demo page. Their testing apcupsd page also has some useful colues to make sure your second-hand UPS is configured properly.

Remember,if you are testing your UPS, you want the computer/device you arecontrolling/monitoring from to be on independent power, so you don'tshut off your monitor accidentally!

The apcupsd on-line manual has a section that explains which UPS types use the APC Smart protocol, and the APC smart protocol page has clues for the serial communications itself, for the application-side hackers.

The Redhack.org site has a few older pages that discuss the APC cabling (deeplink)for various APC UPSs, in relation to early versions of apcupsd.

There is also a useful pinouts page in russia (pinouts.ru)with a UPS section that includes APC (Smartand dumb) as well as other vendor's devices. (I was cautiousabout visiting the site, but I've used it a number of times now with nomalware troubles. Use caution anyway...always practice safe hex.)

Besides searching for apcupsd serial cable, you can also look forinformation under NUT (for 'Network UPS Tools') which are available fora few Linux OSs. I found a basic page about using NUT with an APC UPS on engadget

Sperial Port Speeds

(As a Best Practice, always ensure that your physical link is in placebefore you waste time on serial port settins. )

I've run into a few APC UPS ports. They've responded at 2400-8-N-1, butnot at 9600 bps. I've found articles that say to try 19,200 bps, but I haven'tfound any that respond at that speed. I agree that my sample set is relativelysmall, and my not be representative of the majority of APC serial ports deployedto date, but it is my only experience so far.

Apc Rj45 Serial Cable Pinout

By all means, if 2400 8N1 doesn't seem to work for you, try other settings.(After you have made sure that your physical link is correct and connected!)

RJ45 Serial Pinout Options And Diagrams – Opengear Help Desk

Now that you have a User Name: prompt, try the default apc (with the default password of apc.

Jon Steiger has a good web page for the APC SNMP module,which mentions some different serial speed possibilities, and also discusses APC's password recovery process.

APC SmartUPS RT 5000 Console Cable Issue - APC By Schneider ...

Jeff Liebermann posted some ASCII art cable diagrams, and mentions that some APC SNMP adapters will let you change the serial port speed, but the default is 2400 bps.

APC Remote PDU Serial Console Signals

These signals are derived from my testing of an APC model AP7868 smart PDU. I was able to make a 3-wire connection to a Lantronix ETS32PTR terminal server. There is a small voltage present on the RJ-13 pins 1 and 6. I'm not sure if it is the same voltage bus (maybe just for a pull-up signal?).


  • Links that I used to get started;

As you can see, there are tidbits of information, and some of it is conflicting. Unfortunately, this page will only add to the mix. Since I didn't find a single 940-0144A cable around a 120-plus PDU installation, I cannot confirm the pinouts shown in these other (offsite) links. However, I will comment on some of the inconsistencies that led me to my experiment;

  • I've had very good luck using info from pinouts.ru
    • I was initially cautious about visiting a Russian domain, but have had no troubles with that site
  • I was really happy to find the PDF at
  • Opengear
    • The info at the bottom of the page about looping RJ-14 pins 1 and 5 seems to be incorrect.
    • It looks like the original cables connect RJ14 pins 1 and 6 to Chassis Ground on the PC
    • Since this wasn't tying to Signal Ground, I decided to try without any connections...

Armed with enough examples to have a starting point (yes - it is RS-232, there are two possible Ground pins), I then took out my DVM (digital voltmeter) and my Siemon MODAPT, to try to verify signals, and reconcile the differences that I'd read about, using one of our APC model AP7868 PDUs. Here's what I found;

  • Pin1 -2v (in reference to Pin2)
  • Pin2 GND (0v potential to Pin5)
  • Pin3 TxD output (-5.5v in reference to Pin2)
  • Pin4 RxD input (0.2V in reference to Pin2)
  • Pin5 GND (0v potential to Pin2)
  • Pin6 -2v (in reference to Pin2)

I still need to try to determine if the Ground on RJ-14 Pin 2 is the same as Pin 5. (That is, zero-ohm continuity, or some other resistance/impedance.) I also don't know whether tying RJ-14 Pin 1 and Pin 6 together accomplishes any electrical/logical changes. For now, letting both Pin 1 and Pin 6 float (no connection) has not made a measurable difference for an RS-232 connection.
(Other notes in my blog.)

This has been tested with the AP7868 rPDU, and I'll have an AP7900 to test soon.

Specialty cables between the rPDU and Console Servers

(Lantronix Users can use the Cisco Console adapters. So can Opengear users, if your device uses the Cisco wiring schema.)



APC Smart-UPS 5G Cable Pinout Diagram @ Pinoutguide.com



Apc Rj45 Serial Cable Pinout Box

NOTICE: Most of the pages, articles, and tutorials on this website are copyrighted works. You may make 'deep links' to various pages. (If you let me know which page(s) you are linking to, I'll let you know if I move the page(s) during updates.) Please send me email if you wish to republish any material, or use it on your own website.

APC RJ12 Serial Cable Pinout Diagram @ Pinouts.ru

Copyright 1996-2011,David K. Z.Harris, N6UOW
Questions? Comments? Additions? Email consoles atconserver.com.
(Don't harvest my address, I don't wantSPAM!)
How does he do it? AndWhy?